Implementation on DSP of an active contour algorithm for endocardium tracking in echocardiographic images
Research Group
Diseño Electrónico y Técnicas de Tratamiento de SeñalesKnowledge Area
ElectrónicaSponsors
This work has been supported by Fundación Séneca of Región de Murcia and Ministerio de Ciencia y Tecnología of Spain, under grants PB/63/FS/02 and TIC2003-09400-C04-02, respectively.Publication date
2005-05Publisher
The Society of Photographic Instrumentation EngineersBibliographic Citation
ZAPATA PÉREZ, Juan Francisco y RUIZ MERINO, Ramón Jesús. Implementation on DSP of an active contour algorithm for endocardium tracking in echocardiographic images. En: Proceedings of SPIE (2005: Sevilla) Proceedings of SPIE : Bioengineered and bioinspired systems II. Bellingham: SPIE, 2005, vol.5839. Pp. 420-430. ISBN 0-8194-5834-1Keywords
Arquitectura VLIWProcesador DSP
Contornos activos
VLIW Architecture
DSP Processor
Active contours
Abstract
In first place, in this paper, the basic process of parallel code implementation is discussed for a VLIW architecture.
Parallel code modules allow the implementation of a contour active (snake) for segmentation and tracking of
endocardium in echocardiographic images. In second place, this work discusses the performance obtained through
this design model. In this case, it is necessary to check performances in order to obtain a qualitative and
quantitative measurement of our implementation. We have chosen one example which permits to understand
the methodology used in order to obtain the maximum performance of hardware features of VLIW processor:
the distance between points of active contour, very used in different modules composing the active contour
algorithm.