Mostrar el registro sencillo del ítem

dc.contributor.authorLucas Miralles, Manuel 
dc.contributor.authorZamora Parra, Blas 
dc.contributor.authorSánchez Kaiser, Antonio 
dc.contributor.authorViedma Robles, Antonio 
dc.date.accessioned2009-01-07T12:16:11Z
dc.date.available2009-01-07T12:16:11Z
dc.date.issued2006-04
dc.identifier.citationLUCAS, M., KAISER, A.S., VIEDMA, A. ZAMORA, B. Energy optimization of air conditioning system using hydrosolar roof as heat sink. Solar Energy, 38 (4): 448-458, 2006. ISSN 0038-092Xes
dc.identifier.issn0038-092X
dc.description.abstractAn environmentally friendly alternative device, called Hydrosolar Roof, designed for heat dissipation in buildings has been necessary to include all the elements in a global model. Then, three main subsystems have been considered: Cooling Machine, Hydraulic Network and Hydrosolar Roof. A description of the three subsystem is done and the mathematical model is presented.The Cooling machine thermodynamic model has been carried out using EES (Engineering Equation Solver). The Hydraulic network model has piping, pump and nozzle information. The Hydrosolar Roof direct contact heat and mass transfer simulation has been development with a CFD code. Special attention has been paid on the cooling efficiency. The global model has been applied to a real prototype facility experimentally tested. All the energy consumptions have been calculated for different pumping heads. A global coefficient of performance (COP) has been defined and the optimum value obtained.es
dc.description.sponsorshipThe authors wish to acknowledge the collaboration in the calculations of A. Navarro, as well as José María Galán, Energy, Comfort and Enviroment S.L. Manager, as the proporser of the original idea.es
dc.formatapplication/pdf
dc.language.isoenges
dc.publisherElsevier Sciencees
dc.rightsCopyright © 2008 Elsevier B.V.es
dc.rightsVersión del editor: http://www.sciencedirect.com/science?_ob=ArticleListURL&_method=list&_ArticleListID=849306022&_sort=d&_st=4&_acct=C000053933&_version=1&_urlVersion=0&_userid=1595570&md5=a6459f3773c77659c14c1c3fd890106d
dc.titleEnergy optimization of air conditioning system using hydrosolar roof as heat sinkes
dc.typeinfo:eu-repo/semantics/articlees
dc.subject.otherMecánica de Fluidoses
dc.subjectTamaño de gotaes
dc.subjectAire acondicionadoes
dc.subjectChimenea solares
dc.subjectTorre de refrigeraciónes
dc.subjectEnergía solares
dc.subjectDrop size
dc.subjectAir conditioning
dc.subjectSolar chimney
dc.subjectCooling tower
dc.subjectSolar energy
dc.identifier.urihttp://hdl.handle.net/10317/605
dc.identifier.doi10.1016/j.solener.2005.05.012