Analysis and evaluation of 2,2,2- trifluoroethanol/ionic liquids as new
Ver/
Identificadores
URI: http://hdl.handle.net/10317/9798ISBN: 978-84-606-8931-7
DOI: 10.31428/10317/9798
Compartir
Estadísticas
Ver Estadísticas de usoMetadatos
Mostrar el registro completo del ítemGrupo de investigación
Universitat Rovira i Virgili, Department of Mechanical Engineering, Group of Applied Thermal Engineering – CREVERPatrocinadores
This research project was financially supported by the FP7-People- 2010-IRSES Program (NARILAR -New Working Fluids based on Natural Refrigerants and Ionic Liquids for Absorption Refrigeration, Grant Number 269321) and the Spanish Ministry of Economy and Competitiveness (DPI2012-38841- C02-01. Hifni M. Ariyadi are grateful to the fellowship from Universitat Rovira i Virgili–Fundació Caixa Tarragona.Realizado en/con
Universidad Politécnica de CartagenaFecha de publicación
2015Editorial
Universidad Politécnica de CartagenaCita bibliográfica
Ariyadi, Hifni Mukhtar; Coronas, Alberto. Analysis and evaluation of 2,2,2- trifluoroethanol/ionic liquids as new working pairs for heat transformers. En: IX Congreso Nacional de Ingeniería Termodinámica: libro de actas. Cartagena: Universidad Politécnica de Cartagena, Servicio de Documentación, 2015. Pp. 428-434. ISBN: 978-84-606-8931-7Palabras clave
Heat transformerIonic liquid
2,2,2-trifluoroethanol
Performance
Resumen
In this work, the performance of new proposed 2,2,2-trifluoroethanol/ionic liquid mixtures for
absorption heat transformer applications is studied. The 1-ethyl-3-methylimidazolium
tetrafluoroborate ([emim][BF4]) and 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4]
have been selected as new absorbent for absorption heat transformer systems with 2,2,2-
trifluoroethanol (TFE) as refrigerant. The selection of these ionic liquids is based on a computationalexperimental
study to select suitable ionic liquids with optimized properties for TFE absorption
applications.
The performance of these two TFE/ionic liquid mixtures is analysed and evaluated. The solution
concentration (i.e. refrigerant in ionic liquids) in absorber and generator are predicted based on
experimental vapour-liquid equilibrium data. The experimental data of both vapor liquid equilibrium
and excess enthalpy of the mixture are correlated using Non-Random Two Liquid (NRTL) method
available in Aspen Plus ...