Show simple item record

dc.contributor.authorMartínez Galán, José María 
dc.contributor.authorViedma Robles, Antonio 
dc.contributor.authorLucas Miralles, Manuel 
dc.contributor.authorMartínez Martínez, Pedro 
dc.contributor.authorGemelli, Mario 
dc.date.accessioned2020-07-13T22:51:48Z
dc.date.available2020-07-13T22:51:48Z
dc.date.issued2002
dc.identifier.citationGalán, J.M.; Viedma, A.; Lucas, M.; Martínez P. and Gemelli, M.. “The solar roof of Enercom, as an integrated energy solution for thermal conditioning of buildings”. En: Eurosun 2002: 4th ISES (International Solar Energy Society) Europe Solar Congress, Bolonia, 23-26 de Junio 2002.es_ES
dc.identifier.isbn88-900-8930-X
dc.description.abstractActually and in the near future, due to the necessity of refrigeration, the need of thermal energy dissipation systems will be increased. One of the best element, is the cooling tower, but it has one mean inconvenient, what is the use of a fan. The use of the fan has the following misfortunes: waste of energy, noise, vibration and dissemination of Legionella, if it is present. To overcome these misfortunes, we present a energetic solution, highly efficiently, The Solar Roof of Enercom, because the draught of the air, is by natural driving, this element has the following advantages: No electric energy wasted, no noise, no vibration and dramatic reduction of Legionella dissemination in the air. Integrated in an air conditioning system, the solar roof works in different ways according to the needs of the conditioned building, in summer as a heat sink and in winter as a source of heat.es_ES
dc.description.sponsorshipThe authors wish to have the acknowledge to the DG XII (Research) of the European Commission for his economical support, under the Cooperative Research project entitle IMPROVEMENT OF ENERGY POWER OF SOLAR ROOF BY VENTILATION WITH A LINEAR STATIC EXHAUSTER.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherISESes_ES
dc.titleThe solar roof of Enercom, as an integrated energy solution for thermal conditioning of buildingses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.subjectCoolinges_ES
dc.subjectToweres_ES
dc.subjectSolares_ES
dc.subjectRoofes_ES
dc.subjectThermales_ES
dc.subjectConditioninges_ES
dc.subject.otherMecánica de Fluidoses_ES
dc.identifier.urihttp://hdl.handle.net/10317/8653
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.subject.unesco3309.22 Refrigeraciónes_ES