Mostrar el registro sencillo del ítem

dc.contributor.authorVigueras Rodríguez, Antonio 
dc.contributor.authorViedma Robles, Antonio 
dc.contributor.authorRuz-Vila, Francisco de Asís 
dc.contributor.authorVigueras Campuzano, Antonio 
dc.date.accessioned2020-06-25T11:23:30Z
dc.date.available2020-06-25T11:23:30Z
dc.date.issued2005
dc.identifier.citationVIGUERAS RODRÍGUEZ, Antonio et al. Towards an overall simulator for a synchronous wind energy system. En: First International Congress of Energy and Environment Engineering and Management (CIIEM), Portoalegre, 2005. ISBN 84-934089-9-9.es_ES
dc.identifier.isbn84-934089-9-9
dc.description.abstractThe amount of electrical energy obtained from renewable sources, specially wind energy, is rising quickly. The interface of this distributed generation with the electrical network will have soon an important influence on control, power quality and voltage stability issues of the whole energy net. In order to be prepared to that change it is necessary to simulate, with a sensible accuracy, the transient events, which happen during normal operation or during faults, and have influence in either net or inner variables. So in this way, it is important to model a wind energy system, taking into account every subsystem that have a significant influence over the transient behavior of the compound system. Some important and recent papers are oriented to analyze the stability [1] and the power quality of the wind systems [2]. In the first one, a doubly fed generator is analyzed from an electrical stability point of view; and in the second one the RMS values of the main electrical variables have been simulated in an overall wind energy system. An interesting paper describing the transient problems in relation with the grid integration of wind turbines can be seen in [3]. In this paper, as a preliminary design of an overall simulator, a variable speed system with a wound rotor synchronous generator is analyzed and a connection of the windmill with a variable wind is simulated.es_ES
dc.description.sponsorshipThe authors are thankful to the support from the Caja de Ahorros del Mediterraneo (BECA-CAM predoctoral 2003, a grant conceded to the first author). This research is partially supported by the Consejeria de Educación y Ciencia de la Comunidad Autónoma de la Región de Murcia (Project Séneca 2002: PC-MC/3/00074/FS/02).es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherb@becedarioes_ES
dc.titleTowards an overall simulator for a synchronous wind energy systemes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.subject.otherMecánica de Fluidoses_ES
dc.subjectElectrical energyes_ES
dc.subjectRenewable sourceses_ES
dc.subjectWindmiles_ES
dc.subjectWind energyes_ES
dc.identifier.urihttp://hdl.handle.net/10317/8619
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.relation.projectIDPC-MC/3/00074/FS/02es_ES
dc.subject.unesco3322.05 Fuentes no Convencionales de Energíaes_ES
dc.contributor.funderCaja de Ahorros del Mediterraneo (CAM)es_ES
dc.contributor.funderConsejeria de Educación y Ciencia de la Comunidad Autónoma de la Región de Murciaes_ES


Ficheros en el ítem

untranslated

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem