%0 Journal Article %A Zapata Pérez, Juan Francisco %A Ruiz Merino, Ramón Jesús %T Implementation on DSP of an active contour algorithm for endocardium tracking in echocardiographic images %D 2005 %U http://hdl.handle.net/10317/1417 %X In first place, in this paper, the basic process of parallel code implementation is discussed for a VLIW architecture. Parallel code modules allow the implementation of a contour active (snake) for segmentation and tracking of endocardium in echocardiographic images. In second place, this work discusses the performance obtained through this design model. In this case, it is necessary to check performances in order to obtain a qualitative and quantitative measurement of our implementation. We have chosen one example which permits to understand the methodology used in order to obtain the maximum performance of hardware features of VLIW processor: the distance between points of active contour, very used in different modules composing the active contour algorithm. %K Electrónica %K Arquitectura VLIW %K Procesador DSP %K Contornos activos %K VLIW Architecture %K DSP Processor %K Active contours %~ GOEDOC, SUB GOETTINGEN