TY - JOUR A1 - Hernández Esteban, Andrés AU - Toledo Moreo, Francisco Javier AU - Martínez Cabeza De Vaca Alajarín, Juan de la Cruz AU - Martínez Álvarez, José Javier AU - Ruiz Merino, Ramón Jesús T1 - FPGA-based implementation of the instantaneus frequency estimation of phonocardiographic signals Y1 - 2004 UR - http://hdl.handle.net/10317/1414 AB - The instantaneous frequency can be used to provide information about how the frequency content of the phonocardiogram signal varies in time, in order to characterize the heart sounds and murmurs. The instantaneous frequency of a signal can be calculated from the discrete Hilbert transform, computed through the moving discrete Hartley transform, which reduces the computation time. To compute in real time the instantaneous frequency, the algorithms have been implemented in a FPGA device, exploiting the high performance and flexibility of reconfigurable hardware. The results obtained from the FPGA show high accuracy in comparison to those computed with Matlab KW - Arquitectura y Tecnología de Computadoras KW - Electrónica KW - Frecuencias de análisis de señal KW - Algoritmos de procesamiento de señal KW - Sistema de diseño asistido por ordenador KW - Transformada de Hilbert KW - Frecuencias instantáneas KW - FPGA KW - Señales fonocardiográficas KW - Frequency signal analysis KW - Signal processing algorithms KW - Computer-aided system design KW - Hilbert transform KW - Instantaneous frequency KW - Phonocardiographic signal LA - eng PB - International Federation of Automatic Control ER -